Air cooled water chillers


CCT 48–420


GENERAL DESCRIPTION

Air cooled water chiller units, with axial fans for outdoor installation.
The range consists of 13 models covering a cooling capacity from 5 to 42 kW.


VERSIONS:

CCT - cooling only
CCT/WP - cooling and heating
CCT/SP - cooling only, with storage tank
CCT/WP/SP - cooling and heating, with storage tank


TECHNICAL FEATURES FOR STANDARD VERSION (1):

Structure

With supporting frame, in peraluman and galvanized sheet. Stainless-steel screws.

Compressor

Scroll ermetic 1-phase (48÷74) or 3-phase (87÷420) compressor, complete with overload protection (klixon) embedded in the motor and crankcase, if needed, installed on rubber vibrations absorbing.

Fans

Axial fan type low ventilation and special wing profile, they are directly coupled to external rotor motors with protection grade IP54, and a safety fan guard fitted on discharge air flow.

Condenser

Copper tubes and aluminium finned coil.

Evaporator

In AISI 316 stainless steel braze welded plates type. The evaporator is insulated with flexible closed cells material. On the heat pump units is always installed an antifreeze heater.

Electrical panel

Includes: main switch with door lock device, fuses, compressor and pump remote control switch (108÷420).

Microprocessor controls the following functions:

regulation of the water temperature, antifreeze protection, compressor timing, alarm reset, potential free contact for remote general alarm, local or remote cooling / heating changeover (operating in heat pump), visual system with digital display: running cycle (cooling or heating), compressor delay relay/on, inlet water temperature, set point and differential setting, alarm decodification.


TECHNICAL FEATURES FOR STANDARD VERSION (2):


CCT version

Refrigerant circuit

The circuit, in copper tubing, includes: dryer filter, expansion valve, manual reset high pressure switch and automatic reset low pressure switch, automatic reset low pressure switch (193÷420) and liquid and humidity indicator (193÷420).

Water circuit

The circuit, in copper tubing, includes: water differential pressure switch and manual air release valve.


CCT/SP version

Refrigerant circuit

The circuit, in copper tubing, includes: dryer filter, expansion valves, manual reset high pressure switch, automatic reset low pressure switch (193÷420) and liquid and humidity indicator (193÷420).

Water circuit

The circuit, in copper tubing, includes: water differential pressure switch, manual air release valve, insulated tank, circulator (48÷87) or pump (108÷420), safety valve (3 bar), gauge, plant charge and discharge shut off valve and expansion vessel.

 

CCT/WP version

Refrigerant circuit

The circuit, in copper tubing, includes: 2-ways dryer filter, expansion valves, check valves, 4-ways reverse valve, manual reset high pressure switch, automatic reset low pressure switch (193÷420) and liquid and humidity indicator (193÷420).

Water circuit

The circuit, in copper tubing, includes: water differential pressure switch and manual air release valve.


CCT/WP/SP version

Refrigerant circuit

The circuit, in copper tubing, includes: bi-directional dryer filter, expansion valves, check valves, 4-ways reverse valve, manual reset high pressure switch, automatic reset low pressure switch (193÷420) and liquid and humidity indicator (193÷420).

Water circuit

The circuit, in copper tubing, includes: water differential pressure switch, manual air release valve, insulated tank, circulator (48÷87) or pump (108÷420), safety valve (3 bar), gauge, plant charge and discharge shut off valve and expansion vessel.


SEPARATELY SUPPLIED ACCESSORIES:

condensation control, circulation pump, remote hydronic module, low pressure switch (48÷177), remote control panel, RS 485 serial interface, coil protection guards, rubber vibration dampers.