With the coolwex “hpg” - ground/water heat pump you gain one of the most economical and reliable method of heating.Coolwex heat pumps enable rational heating during colder months and become an excellent source for cooling your premises on summer days with the temperature acquired from the ground.
|
If you have enough useful earth’s surface, we recommend the usage of horizontal earth collector.Ratio between system investments and availability is the highest, therefore it represents one of the most rationalheating sources. COOLWEX heat pump with horizontal earth collector uses constant earth temperature not only for heating but also for cooling. Polyethylene pipes are laid horizontal 0,8 to 1,2 m under the ground in minimal distance 0,7 m beetwen two pipes. Inside pipes circulate mixture of water and glycol, which takes from the earth heat for evaporating the refrigerant. Required area for horizontal earth collector is 1.5 to 2.0 times bigger than “neto” heating surface in the house. Size of required surface depends on heating demands, heat pump capaticy and earth quality. Amount of transfered energy on equal surface of collector, depends on earth moisture. |
Ground/water system
(horizontal earth collectors) |
COOLWEX heat pump with vertical probe works constant and constantly achieves high COP.It’s the perfect way for heating andcooling in cases you don’t have the required size of earth surface, no groundwater or when the groundwater doesn’t reach required conditions. Polyethylene pipes which guarantee proper heat exchange are inserted into earth borings 100 m or maximal 150 m underground. Probe’s depth depends on heat pump capacity and on structure and quality of earth stratums. COOLWEX vertical probe looks like a double U-pipe. Through inlet pipe flows cooled mixture from heat pump and through second pipe flows warmed mixture back to the heat pump. Dependent on earth quality, we need approximatly 12 to 15 m deep dual vertical probe, to transfer 1,0 kW of heating energy. Total depth of vertical probe can be calculated with heat transfer coefficient from 40 to 60 W/m of the probe. |
Earth/water system
(vertical geothermal probes) |
Ground/water heat pump |
All models have built-in compressor with newest »Copeland« Technology, plate heat exchangers SWEP, Siemens regulation and other components of the best in world recognized manufacturers. All models use environmental friendly refrigerant R407 C. All models have built-in heating circu-lation pump and heating source pump, 3-way switching valve and 3, 6 or 9 kW electrical heater in serial production. |
Serial Siemens regulator offers you to regulate 1 x mixing circuit, 1 x direct circuit, sanitary water heating, sun collectors, pool heating, cascade regulation of two compressors and much more… We can also supply models with bigger heating capacities – HPG 25 and tandems HPGT from 30 to 106 kW. |
Coolwex HPG HPW (.pdf 4.8MB)